DRK166Air-bath film heat shrinkage performance tester, according to ISO14616 air heating principle test method to test the shrinkage performance of heat shrinkable films of different materials, to study the relationship between heat shrinkage force and cold shrinkage force of heat shrinkable films of different materials, and to determine the direction of the test when shrinking. Instrument principle: This tester uses the air heating principle of the multi-station film heat shrinkage performa...


  • FOB Price: US $0.5 - 9,999 / Piece
  • Min.Order Quantity: 100 Piece/Pieces
  • Supply Ability: 10000 Piece/Pieces per Month
  • Port: Shenzhen
  • Payment Terms: L/C,D/A,D/P,T/T
  • Product Detail

    Product Tags

    DRK166Air-bath film heat shrinkage performance tester, according to ISO14616 air heating principle test method to test the shrinkage performance of heat shrinkable films of different materials, to study the relationship between heat shrinkage force and cold shrinkage force of heat shrinkable films of different materials, and to determine the direction of the test when shrinking.

    Instrument principle:

    This tester uses the air heating principle of the multi-station film heat shrinkage performance tester to test the shrinkage force, shrinkage rate and other properties of various heat shrinkable films, so as to compare the performance differences of shrinkage films produced with different materials and raw materials, and is suitable for testing Heat shrinkable film of different materials.

    Experimental way:

    Place the heat shrinkable film on a fixture with a displacement sensor or a force sensor, and obtain the heat shrinkage force, cold shrinkage force and maximum shrinkage by testing the shrinkage performance curves of the film over time after being heated in a closed heating chamber. rate result value.

    Instrument characteristics:

    1. The test of 1~3 groups of samples can be completed at the same time, and the detection efficiency is high.

    2. The system displays the heat shrinkage force, cold shrinkage force and thermal shrinkage rate in real time during the test.

    3. The system provides historical data query and printing functions, and intuitively displays the test results to users.

    Technical parameter:

    The equipment is equipped with high-precision force sensor and displacement sensor, which can accurately test the thermal shrinkage parameters of the sample.

    (1) The range of contractile force value is: 0.2~30N

    (2) The accuracy of the test is ±0.2%

    (3) The displacement range is 0.125~45mm

    (4) The test accuracy is ±0.125mm

    (5) The testable temperature range is room temperature ~ 210℃

    (6) The temperature control accuracy is ±0.5℃

    (7) Dimensions: 700X400X390